coal boiler 15 ton h 300degre and 31 bar

COAL FIRED BOILER – PRINCIPALS

19 Oct 2015 7. 8 p [bar] T [C] h [kJ/kg] M [kg/s] x [-]. Typical 700 MW. 38.61 p. 330.8 T. 3048 h. 27.84 M. 23 p. 478.2 T. 3416 h. 47.42 M. 7 p. 320.5 T. 3102 h.

BOILERS | Energy-Models.com

The quantity of the steam produced is indicated in tons of water evaporated to steam per hour. Most coal-fired power station boilers use pulverized coal, and many of the Percentage heat loss due to evaporation of water formed due to H2 in fuel A 10% blow down in a 15 kg/cm2 boiler results in 3% efficiency loss.

Boiler Product Catalog

Specification of Package and Shop-assembled Water Tube Coal-fired Boiler Furnace. Rated Evaporation Capacity. (t/h). 4. 6. 6. 8. 10.0. 15. 20. 25 31. 35.12. Suitable Fuel. Designed Coal Type. AII. AII. AII. AII. Low heating Value. (KCAL/kg).

OIL FIRED BOILER CONVERSION TO PULVERIZED COAL | Project

End date 31 March 1985 This is to be achieved by use of a new type of pulverized coal combustor generating a After two weeks for calibration and control adjustment the boiler arrived at its design specification of 40 T/h steam production at 74 Bar-500 C. During tests, the boiler load was 35-36 T/h (88-90 % capacity).

Boiler Efficiency – cloudfront.net

120 t/hr. Characteristics. • High Capital Cost. • Used for high pressure high 31 for every 1% reduction in excess air,0.6% rise in efficiency. The optimum excess air level varies 15 -20. Pulverized coal. Partially water – cooled furnace for dry ash removal At 8 bar g and orifice size of 10 mm, steam leakage is 250 kg/h.

Chapter 4.1: Boiler Short type questions 1. In the absence of steam

The feed water flow into the boiler can be used as an effective tool to quantify h = Enthalpy of fed water kcal/kg For solid fuel: The accurate measurement of the flow of coal or other solid fuel is very difficult. Ratio of bottom ash to fly ash 15: 85 T(xCxm a f. P. −. = 100x. 5060. )4.32. 160(x23.0x31.9 −. L1. = 5.40 %. 2.

Range of Products and Services 5 MB Download

leader for “Grate Firing Systems” and “Gasifying and Direct Melting Furnace Systems”. With more than 350 80 t/h at a pressure of 42 bar and a temperature 8,0 / 15,0 / 10,5 MJ/kg Operating approval. EU Requirements. Year of commissioning. 2002. 31. 30 existing steel supporting structure of the old coal-fired boiler.

1. energy performance assessment of boilers – Knowledge

1.6 TPH. GCV of coal. : 4000 kCal/kg. Calculation. 100. ) (. )( x. GCVxq. hHxQ efficiency. Boiler. −. = η. Where Q. = Quantity of steam generated per hour (kg/hr).